60 Words Block Format for Mailbox Out Message Request (Output Image)
Word Offset
Start End Name Description
0 0 Block ID Block number 100
1 60 Mailbox Message
Mailbox output message for module (first 60 words of
mailbox message)
Word Offset
Start End Name Description
0 0 Block ID Block number 101
1 60 Mailbox Message
Mailbox output message for module (second 60
words of mailbox message)
Word Offset
Start End Name Description
0 0 Block ID Block number 102
1 24 Mailbox Message
Mailbox output message for module (last 24 words of
mailbox message)
25 60 Reserved Reserved for future use
After the module receives the mailbox request, it immediately sends a input block
with the same Block ID as confirmation that the mailbox request block was
received.
60 Words Block Format for Mailbox Out Message Response (Input Image)
Word Offset
Start End Name Description
0 0 Block ID
Block number 100 to 102 (Same as original
requesting block IDs.)
1 1 Output Index
Index of Output image to receive (1 to 16 for data, 0
or -1 if no data)
2 2 Mailbox Status Status of out mailbox request
3 61 Reserved Reserved for future use