MVI69 Output Data Block
This block contains the PROFIBUS cyclic output data to be sent from the
processor to the module and to the PROFIBUS slaves on the network.
240 Words Output Data Block Format (Output Image)
Word Offset
Start End Name Description
0 0 Block ID Block number 1 to 4
1 200 Output Data PROFIBUS Output Data
201 201 Last Out Mailbox ID
Last out mailbox message ID sent through output
image
202 202 Last In Mailbox ID
Last in mailbox message ID processed from input
image
203 203 Last Alarm ID Last alarm message ID processed from input image
204 205 PROFIBUS CRC PROFIBUS CRC32 value
206 207 Module CRC Module CRC32 value
208 240 Reserved Reserved for future use
120 Words Output Data Block Format (Output Image)
Word Offset
Start End Name Description
0 0 Block ID Block number 1 to 8
1 100 Output Data PROFIBUS Output Data (100 words of data)
101 101 Last Out Mailbox ID
Last out mailbox message ID sent through output
image
102 102 Last In Mailbox ID
Last in mailbox message ID processed from input
image
103 103 Last Alarm ID Last alarm message ID processed from input image
104 105 PROFIBUS CRC PROFIBUS CRC32 value
106 107 Module CRC Module CRC32 value
108 120 Reserved Reserved for future use