Reference PS69-DPS CompactLogix or MicroLogix Platform
User Manual Profibus DP Slave Communication Module
Page 98 of 108 ProSoft Technology, Inc.
May 9, 2014
DPV1 Class 1 Alarm Request
Failure
Description
0
TASK_F_OK
No error
115
DPS_ERR_DIAG_TOO_LONG
Status data exceeds the length of the diagnostic buffer.
116
DPS_ERR_NO_FREE_DIAG_BUFFER
No diagnostic buffer available at the moment
This Error will be temporary.
119
DPS_ERR_ALRM_DPV1_C1_DEACTIVATED
DPV1 class 1 services are disabled
120
DPS_ERR_ALRM_OVERFLOW
Maximum number of active alarms exceeded
121
DPS_ERR_ALRM_DISABLED
Alarm is disabled
123
DPS_ERR_ALRM_ILLEG_LEN
User specific alarm data of illegal length
125
DPS_ERR_ALRM_ILLEG_SEQU
Sequence number out of range or already in use
152
TASK_F_MESSAGECOMMAND
Unknown command in "Command" Field
165
TASK_F_DATA_CNT
Mismatch between length in "length" field and length of message data
200
TASK_F_NOT_INITIALIZED
Task not initialized