Contents ILX69-PBS ♦ CompactLogix or MicroLogix Platform
User Manual PROFIBUS Slave Communication Module
Page 66 of 102 ProSoft Technology, Inc.
March 20, 2015
DPV1 Alarm
The DPV1 Class 1 Alarm Request is used to indicate a DPV1 Alarm to the master. The
MSG instruction Request/Response format is as follows.
ILX69PBS.CONTROL.DPV1.Alarm.Request
Status of Alarm Request message
Type of received alarm specified
Slot number module causing alarm
ILX69PBS.CONTROL.DPV1.Alarm.Response
Status of Alarm Request message, 0 = OK
Type of received alarm specified
Slot number module causing alarm
Komentarze do niniejszej Instrukcji