Reference MVI69-S3964R CompactLogix or MicroLogix Platform
Siemens 3964R Protocol
ProSoft Technology, Inc. Page 61 of 80
October 31, 2008
Send Block for Module to send to CP (Block 1)
Offset Data Length
0 9X1X 1
1 Header 10
11 Data 50
Send Block for Module to send to CP (Blocks 2 to 4)
Offset Data Length
0 9X2X, 9X3X, 9X4X 1
1 Data 60
Request for data Block from Module to respond to CP
Offset Data Length
0 910X 1
1 Reserved 2
3 1145h 1
4 Data Block (DB) 1
5 Data Word (DW) 1
6 Number of Data Words 1
7 Coordination Bytes 1
8 Data Type (4Dh/44h) 1
9 to 12 Reserved 4
Receive Data from CP (First Block)
Offset Data Length
0 910X 1
1 Reserved 1
2 Data Block 1 1
3 1141h/11FFh 1
4 Data Block (DB) 1
5 Data Word (DW) 1
6 Number of Data Words 1
7 Coordination Bytes 1
8 Data Type (4Dh/44h) 1
9 to 12 Reserved 4
13 Data 49
Receive Data from CP (Blocks 2 to 4)
Offset Data Length
0 910X 1
1 Reserved 1
2 Data Block (2 to 4) 1
3 Data 59